Tel: +86-13714720278     E-mail: info@hotplates.cn

About   Contact    |   

Intelligent Graphite Digester - Your Website Name

HIGH TEMP HOT PLATE/

Intelligent Graphite Digester

Intelligent Graphite Digester The intelligent graphite digester adopts a high-throughput 56-hole design to realize rapid batch pretreatment of massive samples for high-volume digestion laboratories. It uses high-purity graphite as heating medium with inter-hole temperature difference ≤±1.5℃ for outstanding temperature uniformity. Wireless Bluetooth control isolates operators from corrosive acid fumes and high heat for improved safety. Simple operation and fast digestion make it an ideal pretreatment instrument for elemental analysis of various samples. 1. Key Performance Features Full Color Touchscreen Operation Equipped with tablet-style true color touch panel; no internal wiring connectors or physical switches required for full temperature control, delivering a modern, smooth user experience. 3D Surround Uniform Heating for Higher Digestion Efficiency High-purity graphite block features superior thermal conductivity…

  • Product Details

Intelligent Graphite Digester

The intelligent graphite digester adopts a high-throughput 56-hole design to realize rapid batch pretreatment of massive samples for high-volume digestion laboratories. It uses high-purity graphite as heating medium with inter-hole temperature difference ≤±1.5℃ for outstanding temperature uniformity. Wireless Bluetooth control isolates operators from corrosive acid fumes and high heat for improved safety. Simple operation and fast digestion make it an ideal pretreatment instrument for elemental analysis of various samples.dual hot plate electric

1. Key Performance Features

  1. Full Color Touchscreen Operation
    Equipped with tablet-style true color touch panel; no internal wiring connectors or physical switches required for full temperature control, delivering a modern, smooth user experience.
  2. 3D Surround Uniform Heating for Higher Digestion Efficiency
    High-purity graphite block features superior thermal conductivity to deliver consistent heat to all digestion tubes without cold zones. Stereo wrap-around heating minimizes heat loss and compensates the shortcomings of flat heating plates.
  3. Excellent Sample Repeatability
    Inter-hole temperature deviation ≤±1.5℃ ensures identical digestion conditions for every sample, guaranteeing high precision and accurate test data.
  4. Multi-Hole High Throughput, Far Larger Batch Capacity Than Microwave Digestion
    Mass sample processing drastically shortens overall pretreatment time. Standard configuration: 56 holes for 56 × 100 mL liquid samples. Customizable options: 72 / 90 / 110 hole modules. Atmospheric digestion design provides safer and faster operation compared to high-pressure microwave systems.
  5. Premium Corrosion-Resistant Construction, Low Maintenance
    Graphite block coated with PTFE coating for easy cleaning and strong acid/alkali resistance. PTFE worktop with zero exposed metal components around the unit, safe for harsh corrosive laboratory environments.
  6. Android OS + Expert PID Temperature Control System
    Intuitive visual monitoring via PDA-style interface displays real-time digestion parameters including running time, hold duration and current temperature. Users can edit, save and recall customized digestion programs for different matrices.
  7. Genuine Sample Temperature Monitoring
    Optional external temperature probe accessory measures actual sample liquid temperature to guarantee complete, thorough digestion.
  8. Proven Reliability with Established Market Reputation
    12 years of market verification with hundreds of end users; widely recognized for exceptional long-term stability and consistent performance.

2. Technical Specifications (Model DS-360-56)

  1. Model: DS-360-56
  2. Number of digestion wells: 56
  3. Well diameter: 30 mm
  4. Well depth: 60 mm
  5. Temperature control range: Ambient ~ 230℃
  6. Temperature control accuracy: ±0.2℃
  7. Inter-well temperature difference: ≤±1.5℃
  8. Timing range: Up to 24 hours
  9. Control mode: Wireless Bluetooth remote control
  10. Heating medium: High-purity graphite
  11. Worktop material: PTFE panel
  12. Outer cabinet material: Engineering plastic
  13. Temperature sensing: Built-in sensor, external probe optional
  14. Rated power: 2300 W
  15. Overall dimension: 515 × 400 × 150 mmmicroplate heater

3. Performance Comparison of Digestion Heating Equipment

Technical Index Electric Furnace Flat Hot Plate Water/Oil Bath Microwave Digester Graphite Digester
Digestion Type Atmospheric Wet Digestion Atmospheric Wet Digestion Atmospheric Wet Digestion High-Pressure Wet Digestion Atmospheric Wet Digestion
Heating Uniformity Poor Fair Good Good Excellent
Temperature Precision Poor Poor Good Fair Excellent
Temperature Range Uncontrollable Wide Narrow Wide Wide
Sample Throughput Low Medium Low Low Very High
Multi-Step Program Complicated Complicated Not Supported Not Supported Easy & Flexible
Cross Contamination Risk High High High Low Low
Corrosion Resistance Poor Poor Fair Good Excellent
Operation Safety Poor Good Good Poor (High Pressure) Good
Intelligent Control None Basic Only None Moderate Advanced
Purchase Cost Low Medium-Low Medium-Low High Medium-High

4. Wide Application Industries

  • Environmental Monitoring: Wastewater, drinking water, sludge, mineral slurry, industrial effluent, soil heavy metal analysis
  • Agriculture & Food Inspection: Milk powder, aquatic products, vegetables, fruits, tobacco, plant tissue, chemical fertilizer testing
  • Quality Inspection: Cosmetics, non-staple food, general industrial material testing
  • Mining & Metallurgy: Ores, mineral residues, smelting raw materials and finished products
  • Pharmaceutical Industry: Chinese herbal medicine, capsules, ointment raw material digestion
  • Scientific Research: Laboratory analytical experiments, new material project development
  • CDC Disease Control: Biological specimens, human hair heavy metal detectionastro hot plate

5. Standard Maintenance & Safety Operation Guidelines

  1. After each experiment, turn the energy adjustment switch to OFF before cutting the main power supply.
  2. If the instrument will not be used for a long period, unplug the mains plug, store the digester in a dry environment and cover with a plastic dust cover.
  3. Thoroughly clean all surfaces before any maintenance or repair work.
  4. Preserve the original operation manual for reference during daily use.
  5. The manufacturer shall not be liable for property damage, personal injury or equipment failure caused by unauthorized modification of built-in safety protection devices.
  6. No liability will be accepted for losses arising from failure to comply with stated safety preventive measures.
  7. Defects and malfunctions caused by careless operation or violation of manual procedures are not covered by manufacturer liability.
  8. When rapid heating to target temperature, avoid holding the power dial at FULL position for more than 20 minutes continuously; adjust to gear 1–5 according to actual working requirements.
  9. Carry out regular inspection and maintenance to verify all functional parts operate normally, including surface cleaning and safety performance checks.
  10. For surface cleaning, use standard laboratory neutral detergents and industrial clean water.miniature hot plate

6. Key Differences Between Graphite Digester and Microwave Digester

  1. Microwave digesters support high-pressure high-temperature reactions that graphite digesters cannot perform. Meanwhile, intelligent graphite digesters operate under normal atmospheric pressure to complete acid removal and open-vessel digestion tasks unavailable for microwave equipment. The core wet digestion chemical principles of both instruments are largely identical.
  2. Graphite digesters allow supplementary acid addition mid-experiment; microwave digesters require full cooling and opening the vessel to add reagents after a complete digestion cycle.
  3. For samples without high-pressure reaction requirements, graphite digesters can fully replace microwave digestion systems for routine pretreatment.
  4. Throughput gap: Microwave digesters process far fewer samples per batch compared to high-hole graphite digesters.
  5. Cost difference: Anti-explosion microwave digestion systems generally cost 50,000–60,000 RMB or over 100,000 RMB on the market.

Graphite digesters and microwave digesters serve complementary laboratory roles. Microwave equipment enables high-pressure high-temperature digestion, while graphite systems handle atmospheric digestion and post-microwave acid removal workflows, sharing nearly identical sample digestion chemistry principles.

Intelligent graphite digester series pages provide full details including model specifications, product highlights, technical parameters and industrial applications for comprehensive product reference.Customer Case

56-Hole Intelligent Graphite Digester | Atmospheric Sample Pretreatment & Acid Removal Equipment for Environmental & Food Labs

 

Prev:

Next:

Leave a Reply

Leave a message