Constant temperature heating platform with precise temperature control & non-standard customization. We have 10 years of design and manufacturing experience. Modular structure, stable temperature accuracy. Equipped with original Yudian PID intelligent digital temperature controller, solid-state SSR relay and stainless steel heating tubes for easy maintenance and low failure rate.
ETOOL Constant Temperature Heating Platform
1. Main Performance & Features
- Original Yudian PID intelligent digital temperature control system with high precision, safe and simple operation.
- High-quality solid-state SSR relay with service life 100 times longer than ordinary contact relays. Fast response, high reliability, no operating noise, shock resistance, and excellent moisture-proof, mildew-proof and anti-corrosion performance.
- Multiple high-grade stainless steel heating tubes filled with nichrome wire. Superior thermal conductivity, long service life, convenient maintenance and low failure rate.
- Solid pure aluminum plate with high thermal conductivity and even heat distribution. Working efficiency is 5~6 times higher than conventional furnaces, and no deformation occurs under long-time high-temperature operation.
- Housing made entirely of SUS304 stainless steel. No paint peeling or rusting under ordinary working environments.
- The control cabinet is equipped with cooling fans and air vents to prevent overheating of internal components even under extreme working conditions.

2. Application Range
- Soldering and rework of aluminum substrates and LED chips in the LED industry.
- Constant-temperature heating for glue dispensing and potting in all electronics industries.
- Preheating and baking of electronic components.
- Drying and baking of test samples across all industrial sectors.
- Essential heating equipment for biological, genetic, environmental protection, biochemical, analytical and educational laboratories.
ETOOL is a professional heating plate manufacturer. We guarantee stable quality, competitive pricing and thoughtful after-sales service, widely recognized by new and long-term customers. Please contact us for detailed product information.
3. Safety Precautions
- Place the unit on a flat, heat-resistant workbench. Do not cover or touch the heating zone during operation to avoid fire or personal injury.
- Do not operate near flammable, explosive or combustible materials.
- Cut off the power supply and wait until the plate cools down to room temperature before moving the equipment.
- Always turn off the power when not in use to avoid accidents.
- Continuous working time shall not exceed 12 hours.
- Connect the power cord properly to the protective earth for personal safety.
- Slight yellow discoloration on the metal surface after long high-temperature heating is a normal material characteristic.
- Avoid contact with strong acids, alkalis and corrosive chemicals to prevent metal corrosion.
- This device is not waterproof; keep it away from moisture.

4. Operation Manual
4.1 Working Environment
- Power supply: Single-phase AC220V
- Ambient temperature: 0~55℃
- Humidity: below 90%RH, no condensation
4.2 Temperature Setting
- Short press the * parameter key for 0.5s to enter temperature setting mode. One digit will flash. Use arrow keys to modify values and shift positions. Short press the * key again to save and exit. Settings will be stored permanently even after power off.
- The 4-digit digital display supports decimal shifting. Adjust digits with up/down keys, then short press the parameter key to save all values.
- Temporary overshoot before temperature stabilization is normal. Wait until the reading stabilizes before starting the experiment.
4.3 Basic Operation
- Turn on the main switch. Solid red light means continuous heating; flashing light means approaching target temperature; intermittent flash means constant temperature is reached.
- Upper PV window = measured actual temperature; lower SV window = preset target temperature.
- Up/down arrow keys adjust the value; left arrow moves the decimal point.
- No extra confirmation is required; the unit will automatically maintain the set temperature.
4.4 Temperature Offset Calibration
If there is deviation between displayed reading and actual plate temperature:
- Long press the * key until “SHP” appears, then keep pressing until “SCB” is shown.
- Use up/down keys to input positive or negative offset value.
- Long press the parameter key again to save and exit.
Example: If the actual temperature is 10℃ lower than the reading, set PB -10.0; if 10℃ higher, set PB +10.0. All factory parameters are pre-calibrated and generally do not need user modification.
5. Fault Diagnosis
- No power on startup: Check power plug and fuse.
- Display value unchanged, no heating: Heating element is broken; please contact us for replacement.
- High reading on upper window with “HHHH” or “LLL” on lower window: Thermocouple open circuit or controller failure.
6. Product & Industry Coverage
Main products: laboratory instruments, glassware, lab consumables, biological reagents, chemical reagents, microbial products, sample bottles, analytical equipment and meters.
Serving industries including scientific research, pharmaceuticals, life science, education, wastewater treatment, food & beverage, electronics, light industry, mining, oil & gas, petrochemicals, industrial instrumentation and environmental engineering.
あなたのウェブサイト名